Testing and Calibration of Phasor Measurement Units (PMU)

##plugins.themes.academic_pro.article.main##

K. S. Meera
Kaliappan Perumal

Abstract

Phasor Measurement Units (PMUs) and Phasor Data Concentrators (PDCs) are the fundamental components of Wide Area Measurement Systems (WAMS) and Wide Area Monitoring Protection and Control Systems (WAMPACS). PMUs provide fast time-stamped measurement of system parameters such as voltage, current and frequency. They have communication features which help in exchange of large quantities of data quickly. As these measurements are very useful in power system support applications such as system parameter analysis, online voltage stability calculations, adaptive protective algorithms etc. they must always function reliably and accurately. This necessitates that the PMUs be calibrated so that their data is consistent, accurate, and credible, and that the models from different manufacturers are interoperable. The 6135A PMUCAL of fluke make is a unique tool which carries out manual/ automated tests that certify a PMU configuration for meeting the latest performance standards of the IEEE Standard for Synchrophasor Measurements for Power Systems (IEEE C37.118.1:2011, IEEE C37.118.1:2014 and IEEE C37.242). This paper discusses the 6135A PMUCAL – a unique test facility set up at the Power Systems Division of CPRI and also results of typical PMUs tested using this facility.

##plugins.themes.academic_pro.article.details##

How to Cite
Meera, K. S., & Perumal, K. (2018). Testing and Calibration of Phasor Measurement Units (PMU). Power Research - A Journal of CPRI, 1–12. https://doi.org/10.33686/pwj.v14i1.142172

References

  1. Jager FA, Rens APJ. On-line performance monitoring of a transmission line using synchrophasor measurements. Proc IEEE Power Tech; Eindhoven, Netherlands. 2015 29 Jun- 2 Jul. p. 1–5. https://doi.org/10.1109/PTC.2015.7232541
  2. Matica R, Kirincic V, Skok S, Marusic A. Transmis-sion line impedance estimation based on PMU Measurements. Proc IEEE EuroCon 2013; Zagreb, Croatia. 2013 Jul 1-4. p.1438–44.
  3. Matica R, Kirincic V, Skok S. Transmission line positive sequence impedance estimation based on multiple scans of phasor measurements. Proc IEEE Energy Conf (ENERGYCON) 2014; Dubrovnik, Croatia. 2014 May 13-16. p. 644–51.
  4. Zhao X, Zhou H, Shi D, Zhao H, Jing C, Jones C. On-line PMU-based transmission line parameter identification. CSEE J. Power Energy Syst. 2015 Jun; 1(2):68–74. https://doi.org/10.17775/CSEEJPES.2015.00021
  5. IEEE standard for synchrophasor measurements for power systems. IEEE Std C37.118.1-2011; 2011 Dec.
  6. Phadke AG. Synchronized phasor measurements in power systems. IEEE Computer Application to Power. 1993 Apr; 6(2):10–15. https://doi.org/10.1109/67.207465
  7. Phadke AG. Synchronized phasor measurements-a historical overview. IEEE/PES Transmission and Distribution Conference and Exhibition 2002. Asia Pacific. 2002. p. 476-479.
  8. Phadke AG, Thorp JS. History and applications of phasor measurements. PSCE ‘06 Power Systems Conference and Exposition 2006; 2006. p. 331–5. https://doi.org/10.1109/ PSCE.2006.296328
  9. Baldwin TL, Mili L, Boisen Jr. MB, Adapa RA. Power system observability with minimal phasor measurement placement. IEEE Transactions on Power Systems. 1993; 8:707–15. https://doi.org/10.1109/59.260810
  10. Nuqui RF, Phadke AG. Phasor measurement unit placement techniques for complete and incomplete observability. IEEE Transactions on Power Delivery. 2005; 20:2381–8. https://doi.org/10.1109/TPWRD.2005.855457
  11. Real time application of synchrophasors for improving reliability. NERC report. Available from: http://www.nerc. com/docs/oc/rapirtf/RAPIR%20final%20101710.pdf
  12. 6135A/PMU Calibration System, Operators Manual, Fluke Corporation.