Grid Stability and Control in DFIG Wind Turbines using Dynamic Voltage Restorer

##plugins.themes.academic_pro.article.main##

S. Arjuna Rao
Swaraj Kumar Das
B. V. Raghavaiah

Abstract

The development of wind power in India began in the 1990s, and has significantly increased in the last few years.India has the fifth largest installed wind power capacity in the world.As of 31 Jan 2013 the installed capacity of wind power in India was 18551.7 MW, mainly spread across Tamil Nadu (7134 MW), Gujarat (2,884 MW), &Maharashtra (2310.70 MW)whichare leading the top. All across the world, the demand for electricity from renewable energies is constantly growing. To meet this demand, wind farms must be as operable as conventional power plants and better integrated into the grid control mechanism. Our wind power plants should actively support the grid, fulfilling all necessary requirements and ensuring reliable energy supplies even during breakdowns. Wind power plants feed the grid with controlled reactive power. This allows for a constant voltage control, sustaining the line voltage. Even at temporary voltage dips the wind power plant remains connected to the grid and helps to keep it stable. If any frequency fluctuations occur the effective power of our wind turbines should automatically adjust according to the needs.

##plugins.themes.academic_pro.article.details##

How to Cite
Rao, S. A., Das, S. K., & Raghavaiah, B. V. (2013). Grid Stability and Control in DFIG Wind Turbines using Dynamic Voltage Restorer. Power Research - A Journal of CPRI, 431–442. Retrieved from https://cprijournal.in/index.php/pr/article/view/884

References

  1. M. Tsili and S. Papathanassiou, “A review of grid code technical requirements for wind farms,” Renewable Power Generat., IET, vol. 3, no. 3, pp. 308–332, Sep. 2009.
  2. R. Pena, J. Clare, and G. Asher, “Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind energy generation,” Electr. Power Appl., IEE Proc., vol. 143, no. 3, pp. 231–241, May 1996.
  3. S.Muller, M.Deicke, and R.De Doncker, “Doubly fed induction generator systems for wind turbines,” IEEE Ind. Appl.Mag., vol. 8, no. 3, pp. 26–33, May/Jun. 2002.
  4. J. Lopez, E. Gubia, P. Sanchis, X. Roboam, and L.Marroyo, “Wind turbines based on doubly fed induction generator under asymmetrical voltage dips,”IEEE Trans. Energy Convers., vol. 23, no. 1, pp. 321–330, Mar. 2008.
  5. M. Mohseni, S. Islam, and M. Masoum, “Impacts of symmetrical and asymmetrical voltage sags on dfig-based wind turbines considering phaseangle jump, voltage recovery, and sag parameters,” IEEE Trans. Power Electron., to be published.
  6. S. Seman, J. Niiranen, and A. Arkkio, “Ride-through analysis of doubly fed induction wind-power generator under unsymmetrical network disturbance,” IEEE Trans. Power Syst., vol. 21, no. 4, pp. 1782–1789, Nov. 2006.
  7. W. Zhang, P. Zhou, and Y. He, “Analysis of the by-pass resistance of an active crowbar for doubly-fed induction generator based wind turbines under grid faults,” in Proc. Int. Conf. Electr. Mach. Syst. (ICEMS),Oct., 2008, pp. 2316–2321.
  8. G. Pannell, D. Atkinson, and B. Zahawi, “Minimum-threshold crowbar for a fault-ride-through grid-code-compliant DFIG wind turbine,” IEEE Trans. Energy Convers., vol. 25, no. 3, pp. 750–759, Sep. 2010.

Most read articles by the same author(s)