Power Quality Monitoring and Control Using Virtual Instrumentation System

##plugins.themes.academic_pro.article.main##

V. K. Arunshankar
N. Senthil Kumar

Abstract

This paper presents and develops a LabVIEW based mathematical model for power quality analysis and enhancement. The different types of power quality problems such as voltage sag, voltage swell, power frequency distortions, and harmonic distortions can be identified and controlled suitably. Besides standard undisturbed three-phase voltage signal waveforms, six different categories of the PQ disturbances characteristic for real-time power distribution networks can be simulated on the basis of developed virtual instruments: voltage swells, sags, interruptions, high-order voltage harmonics, swells with harmonics and sags with harmonics. Each of simulated PQ disturbances can be predefined and easily changed according to user requirements, using various combinations of the control settings implemented on the virtual instrument front panel. All computations are carried out using LabVIEW 9.0.

##plugins.themes.academic_pro.article.details##

How to Cite
Arunshankar, V. K., & Senthil Kumar, N. (2014). Power Quality Monitoring and Control Using Virtual Instrumentation System. Power Research - A Journal of CPRI, 119–124. Retrieved from https://cprijournal.in/index.php/pr/article/view/843

References

  1. Sincy George, Vivek Agarwal, Optimum Control of Selective and Total Harmonic Distortion in Current and Voltage under Non-sinusoidal Conditions” IEEE Trans On Power Delivery, Vol. 23, NO. 2, pp. 937944, 2008.
  2. H ideaki Fujita, Member, IEEE, and Hirofumi Akagi, The Unified Power Quality Conditioner: The Integration of Series- and Shunt-Active Filters, IEEE Trans On Power Electronics, Vol. 13, No. 2, pp. 315-322, 1998.
  3. Vinod Khadkikar, Enhancing Electric Power Quality Using UPQC: A Comprehensive Overview, IEEE Trans.on Power Electronics, Vol. 27, No. 5, pp. 2284-2297, 2012.
  4. Vinod Khadkikar, and Ambrish Chandra, UPQC-S, A Novel concept of Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Utilizing Series Inverter of UPQC, IEEE Trans. on Power Electronics, Vol. 26, No. 9, pp. 2414-2425, 2011.
  5. Salem Brahman, Nassar Mendalek, and Kamal Al-Haddad, Experimental Design of a Nonlinear Control Technique for ThreePhase Shunt Active Power Filter, IEEE Transactions on Industrial Electronics, Vol. 57, No. 10, pp. 3364-3375, 2010.
  6. Jaume Miret, Member, IEEE, Miguel Castilla, José Matas,Joseph M. Guerrero, Juan C. Vasquez, Selective HarmonicCompensation Control for Single-Phase Active Power Filter with High Harmonic Rejection, IEEE Trans. on Industrial Electronics, Vol. 56, No. 8, pp. 3117-3126, 2009.
  7. Francisco D. Freijedo, Jesús Doval-Gandoy, Óscar Lopez, Pablo Fernández-Comesaña, and Carlos Martinez-Peñalver, Member, A Signal-Processing Adaptive Algorithm for Selective Current Harmonic Cancellation in Active Power Filters, IEEE Transactions on Industrial Electronics, Vol. 56, No. 8, pp. 2829-2840 , 2009.
  8. L oredana Cristaldi, Alessandro Ferrero, Simona Salicone, A Distributed System for Electric Power Quality Measurement” IEEE Trans. on Instrumentation and Measurement, Vol. 51, No. 4, pp. 776-781, 2002.
  9. C. Zang, Y. Wen, Hao wu, IEEE Transmission and Distribution Conference, pp. 2300-2304, 2002.
  10. L . H. Tey,P.L.So, Y. C. Chu, Improvement of Power Quality Using Adaptive Shunt Active Filter, IEEE Trans. on Power Delivery, Vol. 20, No. 2, pp. 1558-1568, 2005.