Performance Improvements with Advanced AC Drives in Plate Shearing Line at Steel Plant

##plugins.themes.academic_pro.article.main##

B. K. Thummar
V. A. Shah
A. K. Panchal

Abstract

This paper represents the comprehensive study, analysis and results achieved by various data evaluation of AC drive system over DC drive system in Essar steel limited in India. With innovations in advanced direct torque control and vector control technologies, performance of AC drives is similar to DC drives in entire speed range. Usage of these advance speed control techniques in AC drives gives excellent results to achieve desired torquespeed characteristics, dynamic response and over load capabilities similar to DC drives. In February 2010, replacement of DC drive system by AC drive system was carried out in hot rolled plate shearing line (PSL), which is cut to length application line in steel plant. Before replacement, design calculation of AC system was carried out for matching the plant requirements. By various technical and fi nancial comparisons, it is found that use of AC drives is more economical in comparison with DC drives.AC drives ensure improvements on energy effi ciency, reliability and enhancement of production with reduction in cost, maintenance and equipment down time. After replacement of DC drives to AC drives, following performancs ase observed in PSL:>p/p<>p/p<>p/p<>p/p

##plugins.themes.academic_pro.article.details##

How to Cite
Thummar, B. K., Shah, V. A., & Panchal, A. K. (2012). Performance Improvements with Advanced AC Drives in Plate Shearing Line at Steel Plant. Power Research - A Journal of CPRI, 207–220. Retrieved from https://cprijournal.in/index.php/pr/article/view/384

References

  1. Krishnan R. “Electrical motor drivesmodeling, analysis and control,” Upper Saddle River New Jersey: Prentice Hall, pp. 411, 2001.
  2. Tsuneo Kurachi, Hidenori Minami, Tetsuzou Azuma. “Application of variable-speed AC drive to Steel plants, fuji electric journal Vol.64,No.10, 1991.”
  3. Rolf Hoppler, Urs Maier, Daniel Ryf and Leopold Blahous. “Multi drives with active front-end technology”, Vector Journal, pp. 34 2010.
  4. Denis Berthtaume, James Maclaren. Thurso, Qbebec, Justifi cation for AC / DC drives, IEEE CH2973-6/91/00M)-0234,1991.
  5. Leonhard W. “Technical university braunchweig, controlled AC drives, a successful transformation from idea to industrial practice, Control Eng. Practice” Vol. 4, No. 7, pp.897–908, 1996.
  6. Peltola “Improving Power factor with variable speed AC drives,” Oy, Helsinki, Finland, EC&M, 2010.
  7. Jordan H E. “Energy effi cient electric motors and their application,” Van Nostrand Reinhold Company Inc ,1983.
  8. Melfi M J. Hart R T. “Considerations for the use of AC induction motors on variable frequency controllers in high performance Applications,” IEEE Textile Film and Fiber Conference, 1992.
  9. Wennerstrom C H. Connors D P. ‘Motor application considerations for adjustable frequency power,” IEEE Pulp and Paper Conference, 1984.
  10. Howard W Penrose, Ph.D, CMRP President, “Success by design reliability services, application and reliability of AC and DC drives in steel industries”.
  11. Ajith. H. Wijenayake, Tom Gilmore and Rich Lukaszewski, Dale Anderson and Gary Waltersdorf. Modeling and Analysis of Shared/Common DC Bus Operation of AC Drives,” IEEE Industry Application Society, New Orleans, Louisiana, 1997.
  12. A guide for users of variable frequency drives. http://5.abb.com/global/scot/scot239.nsf/veritydisplay/046e0b4cdc2fe50ac12574 66003a8443/$File/3ADW000059.pdf.
  13. Stephen Prachyl. http://www.sea.siemens.com/us/internet-dms/dt/DrivesComm/Drives/Docs/VariableFrequencyDrives_ WhitePaper.pdf
  14. James M. Shumberg, http://www.drivesys.com/ac_drives.html